| Model | Authors | Article | Published on | Protocol | Result |
|---|---|---|---|---|---|
| UA-767 | Rogoza AN, Pavlova, TS, Sergeeva, MV. | Validation of A&D UA-767 device for the self-measurement of blood pressure | Blood Pressure Monitoring, 2000, 5:227-231 | BHS |
A/A |
| UA-767 Plus | Zhanna D. Kobalava, Loulia V. Kotovskaia, Olga S. rusakova, Lala A. Babaeva | Validation of UA-767 Plus device for self-measurment of blood pressure | Clinical Pharmacology and Therapy, 2003, 12 (2) | BHS | A/A |
| UA-774 (UA-767 Plus) | Drs. Paolo Verdecchia, Fabio Angeli, Fabrizio Poeta, Gian Paolo Reboldi, Claudia Borgioni, Loretta Pittavini and Carlo Porcellat | Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure | Blood Pressure Monitoring, 2004, 9:225–229 | BHS | A/A |
| UA-787 | Danile Longo, Gianluca Toffanin, Raffaella Garbelotto, Vania Zaetta, Lucio Businaro and Paolo Palatini | Performance of the UA-787 oscillometric blood pressure monitor accoarding to the European Society of Hypertension protocol | Blood Pressure Monitoring, 2003, 8: 91-95 | ESH | Passed all three phases |
| UA-779/631 | Daniele Longo, Olivo Bertolo, Gianluca Toffanin, Paola Frezza and Paolo Palatini | Validation of the A&D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance | Blood Pressure Monitoring. 2002, 7:243-248 | ESH | Passed all three phases |
| UA-85x | Elisa Bonso, Fabio Ragazzo and Paolo Palatini | Validation of A&D UA-85x (UA-851, 852, 853, 854, 855) device for blood pressure measurement | Blood Pressure Monitoring. 2008, 13:339-341 | ESH | Pass |
| UA-704 | Zhanna D. Kobalava, Yulia V. Kotovskaya and Eugeniy Rodionov | Validation of semi-automatic device UA-704 for self-measurement of blood pressure | Blood Pressure Monitoring, 2005, 10:223-225 | BHS | A/A |
| UA-705 | Paolo Verdecchia, Fabio Angeli, Roberto Gattobigio et al | Validation of UA-705 for self-measurement of blood pressure according to BHS protocol | Blood Pressure Monitoring, 2006, 11:223-227 | BHS | A/A |
| UB-511/512 | Fabio Angeli, Mariagrazia Sardone, Enrica Angeli, Salvatore Repaci, Roberto Gattobigio and Paolo Verdecchia | Validation of the A&D UB-511 (UB-512) wrist-cuff device for self-measurement of blood pressure according to BHS protocol | Blood Pressure Monitoring, 2006, 11:349-354 | BHS | B/B |
| TM-2430 | Palatini P, Frigo G, Bertolo O et al. | Validation of the A&D TM-2430 device for ambulatory blood pressure monitoring and evaluation of performance according to subjects' characteristics | Blood Pressure Monitoring, 1998, 3: 255-260 | BHS | A/A |
| TM-2655P | Zhanna D. Kobalava, Yulia V. Kotovskaya, Lala A. Babaeva and Valentin S. Moiseev | Validation of the TM-2655 device for blood pressure measurement | Blood Pressure Monitoring, 2006, 11:87-90 | BHS | A/A |
| TM-2564GP | Zhanna D. Kobalava, Yulia V. Kotovskaya, Eugeniy Rodionov and Valentin S. Moiseev | Validation of the TM-2564G device for in-hospital blood pressure measurement | Blood Pressure Monitoring, 2005, 10:333-335 | BHS | A/A |
| UM-101 | George S Stergiou et al | Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to International Protocol | Blood Pressure Monitoring, 2008, 13:37-42 | ESH | Pass |